Non-Destructive Testing

Vector Corrosion provides non-destructive testing services to help owners and project teams better understand the condition of their structures, identify active deterioration, and reduce uncertainty when planning repairs or maintenance.

In environments like the UAE, where heat, humidity, and chloride exposure can accelerate corrosion, these methods are critical for identifying issues before they become visible. Traditional inspection methods such as visual assessments and hammer sounding mainly identify surface damage, while deeper or early-stage issues may not be visible.

Non-destructive testing allows for a more comprehensive evaluation of both surface and subsurface conditions, helping uncover early-stage corrosion, internal defects, and unknown as-built details.

Methods

Visual Condition Assessment / Defect Mapping

Visual inspection, including defect classification and mapping, is an initial stage of most condition assessments. Our team uses Plan Radar© for digital capture and quantification of defects.

A construction worker wearing a white helmet, orange safety vest with reflective stripes, black cargo pants, and black work boots is examining a cracked concrete wall with a crack running vertically. The worker is kneeling on the ground with one hand holding a tool, possibly inspecting or measuring the crack.
Construction worker in a safety vest and helmet taking notes or measurements on a concrete barrier at a construction site.
An example of the sensor ray paths in a bridge pile from an acoustic tomography test.
Acoustic tomography test results mapped out with varying colours of blues. Each colour represents how fast it took for the rays to pass through the concrete (velocity). Zones with below average velocities may indicate internal defects or corrosion.

Acoustic Tomography

Generates 3D imaging of concrete elements to locate internal defects such as voids, cracking, and honeycombing. This method uses specialised acoustic transmitters and receivers to measure how stress waves travel through the concrete, with slower velocities indicating potential damage.

VCME workers on a pontoon barge conducting an acoustic tomography test with a sensor chain wrapped around a submerged bridge pile, wearing full PPE.

Concrete Resistivity

Identifies areas more susceptible to corrosion by evaluating how easily electrical current flows through the concrete using a surface resistivity meter (Wenner probe). This information helps determine how current will be distributed through the structure, allowing for more effective cathodic protection system design.

A construction worker wearing a white hard hat, safety glasses, a bright yellow and orange reflective safety vest, gray long-sleeve shirt, and yellow gloves is using a Wenner probe against a large concrete wall.

Corrosion Potential Mapping

Creates a visual map of corrosion activity across reinforced concrete structures, helping prioritise repairs and understand the extent of deterioration. Measurements are collected across the surface using a reference electrode to identify differences in electrical potential, which indicate where corrosion is more likely to be occurring. This allows owners and engineers to clearly see how corrosion varies across each structural element, supporting targeted repair strategies and cathodic protection design.

A full half-cell corrosion map of a basement level (B5) showing areas with high, medium, and low corrosion risk using a color gradient from green to red. The map includes labeled points such as A1-A10, X marks for new chloride locations, and various structural elements like site storage, site office, elevator, and water leakages, with annotations for dust sampling and steel corrosion risk.

Corrosion Rate Testing

Measures how quickly steel reinforcement is deteriorating. A small electrical signal is applied to the steel, and the change in voltage is measured to determine how active the corrosion is. This helps identify areas where damage is progressing faster and where more immediate repair or protection may be required.

Workers in safety vests and helmets inspecting railway tracks inside a tunnel.

Stray Current Surveys

A stray current survey is a systematic field investigation used to detect and characterise unintended DC electrical currents entering, leaving, or flowing through reinforcing steel and other metallic components of a concrete structure. The survey typically includes measurements of structure-to-electrolyte potential, current flow, and electrical continuity to identify the presence, magnitude, direction, and likely source of stray currents and to determine their potential impact on reinforcement corrosion or cathodic protection performance.

Moisture Testing

Moisture testing is a field investigation used to characterise the moisture condition of concrete at representative locations, including the presence, distribution, and relative level of moisture within the concrete. The results are used to assess how moisture may influence reinforcement corrosion, electrochemical measurements, concrete resistivity, repair-material performance, and the operation of corrosion mitigation systems.

A person working with a measuring tape and using a moisture meter to perform a Moisture Test on a concrete floor.
A moisture meter displaying a reading of 15.5% with the label 'PIN PROBE' above it. In the background, a person is wearing a high-visibility safety vest and holding the device, with a tape measure and moisture meter probe on a concrete surface.

Ground Penetrating Radar (GPR)

Locates reinforcement, measures cover depth, and identifies as-built conditions within concrete. GPR uses electromagnetic waves to scan below the surface, enabling rapid assessment of large areas and helping project teams understand what is inside the structure. This reduces risk during repairs or modifications by minimising unexpected conditions.

A construction worker wearing a white safety helmet, orange safety vest, gray t-shirt, and watch kneels on the ground, operating a handheld ground penetrating radar device placed on a concrete surface at a construction site.

Impact Echo / Pulse Velocity (IE/PV)

Identifies internal defects such as honeycombing, cracking, and delamination, while also providing insight into in-situ concrete strength. This method uses a small impact and sensors to measure how stress waves travel through the concrete. Vector Corrosion utilizes advanced equipment designed to collect both impact echo and pulse velocity data simultaneously, improving efficiency and providing a more complete assessment of the structure.

Two construction workers in orange safety vests using an impact echo/pulse velocity device on building a ceiling or wall, surrounded by scaffolding and green safety barriers.

Infrared Thermography

Identifies near-surface delamination in concrete across large areas quickly and effectively. As the sun heats the concrete surface, delaminated areas warm at a different rate than sound concrete, creating temperature differences that can be detected using infrared cameras. These results provide a clear visual map of deterioration and help estimate repair quantities.

A worker in a neon safety vest and helmet is using a thermal imaging camera to take photos of industrial pipes or ducts in a dark facility.
A thermal imaging device displays a colorful thermal image with blue, purple, orange, and yellow areas.
A hand holding a ultrasonic thickness (UT) gauge against structural steel supports and baseplates.

Ultrasonic Thickness (UT)

An ultrasonic thickness (UT) gauge is used to measure the thickness of steel elements. UT works by sending an ultrasonic signal through the steel and measuring how long it takes to travel through the material. This allows the remaining thickness to be determined and helps identify section loss caused by corrosion. When original thickness or age is known, this data can also be used to estimate the rate of section loss. UT can also be used to assess components such as bolts for section loss, cracking, or other defects.

Pile Length Testing

Determines the length of steel, wood, and concrete piles and helps identify potential defects along their depth. This method uses a hammer impact and sensors to measure how long it takes for a stress wave to travel down the pile and reflect back, providing insight into pile integrity and continuity. Changes in the signal can also indicate damage or defects along the pile.

Explore Our NDT Project Experience!